70HF-LQC
Butterfly T-shaped Coil 70 mm with suppressed head muscle activation
Typical use:
TBS protocols.
The DuoMAG XT is a powerful and flexible magnetic stimulator built for ease-of-use in both research and clinical scenarios. The system can be controlled via the coils, a PC or the DuoMAG touch-screen for ultimate ease-of-use . A major advantage of the DuoMAG family is the option to seamlessly integrate with other Deymed systems including the TruScan EEG and TruTrace EMG/MEP systems. This flexibility makes the DuoMAG unrivaled in its possibilities as it can be expanded and enhanced to add more options. The system is offered in multiple configurations, from Compact, Cart model and the innovative MagTower that is the first counter-weight balanced arm holder for TMS. The MagTower significantly reduces the difficulty of holding and positioning heavy magnetic coils.
Deymed coils have built-in controls for stimulation and intensity settings. This allows the user full control without needing to avert attention to external panels or triggers. This also allows the TMS system to be used by a single operator.
Shape
Handle
Cooling
Placebo
Stimulator compatibility
Butterfly T-shaped Coil 70 mm with suppressed head muscle activation
Typical use:
TBS protocols.
Butterfly Coil 60 mm with controls and liquid cooling
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls and liquid cooling
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls and liquid cooling for blinded studies.
Butterfly Overlapping Coil 70 mm
Typical use:
Focused long-term cortical stimulation, mainly for rTMS. More comfort for the patient, due to coil design.
Butterfly Coil 70 mm with controls and liquid cooling for blinded studies.
Butterfly V-Shaped Coil 90 mm and 120° angled surface with liquid cooling
Typical use:
Deep stimulation.
Butterfly Coil 70 mm with controls and cooling fans
Typical use:
Focused long-term cortical stimulation, mainly for rTMS. Can be used with the counterweight balanced coil-holder on the MagTower Configuration.
Butterfly Coil 70 mm with controls and cooling fans for blinded studies.
Butterfly Coil 70 mm with controls
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls - for blinded studies.
Butterfly Coil 50 mm with controls
Typical use:
Very focused cortical stimulation, mainly for rTMS. Paired pulse stimulation with twin coil configuration due to smaller size.
Butterfly V-Shaped Coil 120 mm with controls
Typical use:
Deep cortical stimulation.
Butterfly Coil DuoMAG 50 mm T-shaped
Typical use:
Very focused cortical stimulation, mainly for rTMS. Paired pulse stimulation with twin coil configuration due to smaller size.
Butterfly T-shaped Coil 30 mm
Typical use:
Precisely focused stimulation.
Round Coil 100 mm with controls
Typical use:
Stimulation of peripheral nerves or cortical stimulation.
Round Coil 125 mm with controls
Typical use:
Spinal stimulation.
Please note that this product may not be approved by regulatory authorities in your country/region. For more information, please consult with us or our distributor.
*For users in the USA: Product is considered an investigational device. Limited by Federal (or United States) Law only to investigational use.
Product Specification | XT-10 | XT-35 | XT-100 | XT R New product |
---|---|---|---|---|
Pulse mode | Biphasic, repetitive | Biphasic, repetitive, burst | Biphasic, repetitive, burst | Biphasic, repetitive, burst |
Dimensions | 49 cm x 16cm x 38 cm | 49 cm x 16 cm x 38 cm | 49 cm x 16 cm x 38 cm | 49 cm x 25 cm x 38 cm |
Weight | 17 kg | 17.5 kg | 17.5 kg | 26 kg |
Maximum repetition rate | 30 Hz | 60 Hz | 100 Hz | 100 Hz |
Minimum Inter-train Interval | 34 ms | 17 ms | 10 ms | 10 ms |
Pulse width | 290 μs | 290 μs | 290 μs | 290 μs |
Coil Compatibility | Deymed coils | Deymed coils | Deymed coils | Deymed coils |
Main voltage | 100-240Vac 50/60 Hz | 100-240Vac 50/60 Hz | 100-240Vac 50/60 Hz | 100-240Vac 50/60 Hz |
Synchronization | TTL in/out and/or USB | TTL in/out and/or USB | TTL in/out and/or USB | TTL in/out and/or USB |
Communication | USB full control, control on coil | USB full control, control on coil | USB full control, control on coil | USB full control, control on coil |
A motor threshold (MT) can be found at 47% stimulation intensity for the majority of the population (>90%) on all devices. DuoMAG XT-100 can reach 100 pps at 45% intensity. The nearest competitor can only reach 30% intensity at 100 pps.