- ∙ Intuitive dashboard interface
- ∙ User management system
- ∙ Integrated patient database
- ∙ EMG integration
- ∙ Preset protocols
- ∙ Patient report generator
- ∙ MEP study capabilities
The DuoMAG MP-Quad combines four DuoMAG MP stimulators to provide a fully configurable quadripulse (QPS) monophasic TMS system. This combination allows individual control of the amplitude of all stimulators as well as the capability of setting the inter-stimulus interval (ISI) and delivering the defined quadro-pulse stimulation through a single coil. The Quadripulse functionality allows users to deliver precise sub- and supra-threshold conditioning and test pulses, which is a vital component when studying inter- and intra-cortical inhibition and facilitation. The inter-stimulus interval for the four pulses is adjustable either in the supplied control software or via external control through TTL inputs, offering ultimate flexibility in ISI control. DuoMAG MP-Quad allows users to combine two stimulator pulses into a single pulse, providing a pulse amplitude that equates to 134% of a single DuoMAG MP output. The DuoMAG Quad can also be used with four separate coils to carry out interhemispheric (quadrilateral) stimulation.
DEYMED coils have built-in controls for stimulation and intensity settings. This allows the user full control without needing to divert attention to external panels or triggers. This also allows the TMS system to be used by a single operator.
Shape
Handle
Cooling
Placebo
Compatibility
This product is intended for research purposes only.
Please note that this product may not be approved by regulatory authorities in your country/region. For more information, please consult with us or our distributor.
*For users in the USA: Product is considered an investigational device. Limited by Federal (or United States) Law only to investigational use.
We supply a range of accessories for our systems...
Download the DEYMED Accessories catalogue in PDF format from the link on the right.
Contact us if you are interested in any listed accessories.
TMS compatible TruTrace EMG 2ch Headbox, includes two 5-pin DIN connectors (with pins for patient ground and shielding) or individual active and reference 1.5 mm touch-proof connectors.
TMS compatible TruTrace EMG 4ch Headbox, includes four 5-pin DIN connectors (with pins for patient ground and shielding) or individual active and reference 1.5 mm touch-proof connectors.
Advanced liquid coil cooling system ensures efficient performance with minimal noise.
Integration of a coil arm holder for the MagCart.
Programmable pedal footswitch.
Electrically adjustable chair.
Optionally side support for headrest.
Product Specification | DuoMAG MP-Quad | ||||||||
---|---|---|---|---|---|---|---|---|---|
Pulse Mode | Quadripulse, Monophasic, Combine Pair-pulse*, Pair-pulse, Protocol | ||||||||
Maximum Repetition Rate |
|
||||||||
Inter-Stimulus Interval (ISI) | 0 or 1 – 1000 ms | ||||||||
Inter-quadripulse Interval (IQI) | 500 - 2000 ms | ||||||||
Coil Compatibility | DEYMED Coils | ||||||||
Main Voltage | 4x (100-240Vac 50/60 Hz) | ||||||||
Synchronization | TTL In/Out and/or USB | ||||||||
Communication | USB Full Control, Control on Coil | ||||||||
Intended | Research |
* Combine Pair-pulse - The DuoMAG MP-Quad combines two stimulator pulses into one, achieving a pulse amplitude of 134% of a single DuoMAG MP output.