70HF-LQC
Butterfly T-shaped Coil 70 mm with suppressed head muscle activation
Typical use:
TBS protocols.
The DuoMAG Quadropulse System (QPS) combines four DuoMAG MP stimulators to provide a fully configurable quadropulse TMS stimulator. This combination allows individual control of the amplitude of all stimulators as well as the capability of setting inter-stimulus interval (ISI) and delivering the defined quadropulse stimulation through a single coil. The quadropulse functionality allows users to deliver precise sub- and supra-threshold conditioning and test pulses which is a vital component when studying Inter- and Intra-Cortical Inhibition and Facilitation. The inter stimulus interval for the four pulses is adjustable either in the supplied control software or external control via TTL inputs, offering the ultimate flexibility in ISI control. DuoMAG QPS allows users to combine the two stimulator pulses into a single pulse providing a pulse amplitude that equates to 140% of a single DuoMAG MP output. The DuoMAG QPS can also be used with four separate coils to carryout interhemispheric (quadrolateral) stimulation.
Deymed coils have built-in controls for stimulation and intensity settings. This allows the user full control without needing to avert attention to external panels or triggers. This also allows the TMS system to be used by a single operator.
Shape
Handle
Cooling
Placebo
Stimulator compatibility
Butterfly T-shaped Coil 70 mm with suppressed head muscle activation
Typical use:
TBS protocols.
Butterfly Coil 60 mm with controls and liquid cooling
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls and liquid cooling
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls and liquid cooling for blinded studies.
Butterfly Overlapping Coil 70 mm
Typical use:
Focused long-term cortical stimulation, mainly for rTMS. More comfort for the patient, due to coil design.
Butterfly Coil 70 mm with controls and liquid cooling for blinded studies.
Butterfly V-Shaped Coil 90 mm and 120° angled surface with liquid cooling
Typical use:
Deep stimulation.
Butterfly Coil 70 mm with controls and cooling fans
Typical use:
Focused long-term cortical stimulation, mainly for rTMS. Can be used with the counterweight balanced coil-holder on the MagTower Configuration.
Butterfly Coil 70 mm with controls and cooling fans for blinded studies.
Butterfly Coil 70 mm with controls
Typical use:
Focused cortical stimulation, mainly for rTMS.
Butterfly Coil 70 mm with controls - for blinded studies.
Butterfly Coil 50 mm with controls
Typical use:
Very focused cortical stimulation, mainly for rTMS. Paired pulse stimulation with twin coil configuration due to smaller size.
Butterfly V-Shaped Coil 120 mm with controls
Typical use:
Deep cortical stimulation.
Butterfly Coil DuoMAG 50 mm T-shaped
Typical use:
Very focused cortical stimulation, mainly for rTMS. Paired pulse stimulation with twin coil configuration due to smaller size.
Butterfly T-shaped Coil 30 mm
Typical use:
Precisely focused stimulation.
Round Coil 100 mm with controls
Typical use:
Stimulation of peripheral nerves or cortical stimulation.
Round Coil 125 mm with controls
Typical use:
Spinal stimulation.
This product is intended for research purposes only.
Please note that this product may not be approved by regulatory authorities in your country/region. For more information, please consult with us or our distributor.
*For users in the USA: Product is considered an investigational device. Limited by Federal (or United States) Law only to investigational use.
Product Specification | DuoMAG QPS |
---|---|
Pulse mode | Quadro-pulse, Independent, Protocol, Boost |
Dimensions | Standalone: 49 cm x 55 cm x 39 cm (without PC and cables), Standalone: 49 cm x 87 cm x 79 cm (with PC and cables), On Cart: 61 cm x 160 cm x 80 cm |
Weight | Standalone: 70 kg (without PC and cables), Standalone: 78 kg (with PC and cables), On Cart: 78 kg + cart |
Frequency of stimulation at 100% intensity | 2 Hz |
Frequency of stimulation at 50% intensity | 5.6 Hz |
Maximum repetition rate | 8 Hz |
Inter-Stimulus Interval (ISI) | 0 or 1 – 800 ms |
Pulse width (Rise/Decay) | 100, 141 us / 1, 1.41 ms |
Coil Compatibility | Deymed coils |
Main voltage | 5x (100-240Vac 50/60 Hz) |
Synchronization | TTL in/out and/or USB |
Communication | USB full control, control on coil |